Q1: What information do I need to order a part?

 

 

Q2: Where is the serial number or sales order number located?

 

Q3: What type sensor do I have?

Q4: How do I return parts for repair?

Q5: How often should I calibrate?

Q6: What value and gas should I use to calibrate?

Q7: How often should I change the filters?

Q8: Where can I obtain calibration gas?

Q9: I received a new Sentron control board and the bypass does not function.

Q10: I need service, who do I contact?


Q1: What information do I need to order a part?

 

 

Sales order or serial number along with the part number if you know it.

 
     

 

 

 

Q2: Where is the serial number or sales order number located?

 

Both numbers are located on the system data page. They are also on the sensor/monitor as indicated below:

         
   
PrevEx® on the left or right outside of the base of the sensor.
SNR670 Series on the left or right outside of the base of the sensor.
SNR650 FID on the left or right outside of the base of the sensor.
FFA on the left or right wall on the inside of the sensor.
SNR441 FID on the left or right wall on the inside of the sensor.
FTA on a laminated tag attached to the lower part of the sensor.
Viewport behind the door on the side of the sensor.
Sentron Monitor on the back of the display door.
Max 1600 inside the chassis.
DataMax 2, 4 or 8 on the back of the display door.
Varigraph on the back or side of the chassis.
SmartMaxI label on side of SmartMaxI.
SmartMaxII label on bottom of SmartMaxII.
Drawn Sample Cabinet on inside of housing.
Valve body on inside of housing.
DateMax Transmitter on the back of the black bracket.

 

       

Q3: What type sensor do I have?

   

Go to the Product Picture Page here.

 
     

 

Q4: How do I return parts for repair?

   

Click here for the procedure to return material to Control Instruments for repair.

 

       

Q5: How often should I calibrate?

   

If this is not specified by any national codes, your insurance company or local authority, calibrate every month. If the readings do not change every month the time between calibrations may be increased. NOTE: Some sensor types must be calibrated to determine if they are still sensing gas. These sensors should be calibrated more often.

 
       

Q6: What value and gas should I use to calibrate?

   

Check the systems original data page for the value and test gas. If you do not have the system data page contact our sales department with the sensors serial numbers to obtain a new data page.

 

       

Q7: How often should I change the filters?

Start by checking the filter every month. If the filter is clean at one month, check every 3 months. If the filter is still clean, check every 6 months and then at 1 year.

       

Q8: Where can I obtain calibration gas?

   

Calibration gas can be obtained by calling Control Instruments Sales department or your local specialty gas distributor.

 
       

Q9: I received a new Sentron control board and the bypass does not function.

   

New Sentron monitors and PRB236 control boards do not have active bypass switches. See document H7SEN088 to make the bypass switch active. This document should be included in the manual with the new board or monitor.

 
       

Q10: I need service, who do I contact?

   

Contact the service manager at 973-575-9114 x134. If he is not available contact sales. Service will be scheduled upon receipt of your purchase order.

 
       

 


 